No registrations found.
ID
Source
Brief title
Health condition
breast cancer; neoadjuvant therapy;
borstkanker; neo-adjuvante therapy
Sponsors and support
Intervention
Outcome measures
Primary outcome
a) What changes in phospomonoester / phosphodiester ratio can be detected with 7T MRS during neo-adjuvant therapy in breast cancer?
b) What is the correlation of these changes to the treatment efficacy as determined by pathology?
Secondary outcome
c) How accurate can phospho-esters be determined with in vivo 7T MRS compared to ex vivo analysis?
d) How well do these values relate to the values obtained in preclinical studies?
Study objective
Metabolic changes are thought to precede morphological or changes in tumor size. MR spectroscopy can monitor metabolic changes
Study design
Patients get a MRS scan prior to-, half way-, and after chemotherapy.
Intervention
none
Heidelberglaan 100
W.J.M. Kemp, van der
Utrecht
The Netherlands
088-7556674
w.j.m.vanderkemp@umcutrecht.nl
Heidelberglaan 100
W.J.M. Kemp, van der
Utrecht
The Netherlands
088-7556674
w.j.m.vanderkemp@umcutrecht.nl
Inclusion criteria
- 18 year or older
- Female
- Neoadjuvant therapy for breast cancer
Exclusion criteria
- Prior surgery for malignancy to ipsilateral breast
- Karnofsky score =< 70
- Pregnant or lactating
- Other contraindications for MR
Design
Recruitment
Followed up by the following (possibly more current) registration
Other (possibly less up-to-date) registrations in this register
No registrations found.
In other registers
Register | ID |
---|---|
NTR-new | NL4410 |
NTR-old | NTR4652 |
CCMO | NL36429.041.11 |
OMON | NL-OMON38209 |
Summary results
2. Klomp DW, van de Bank BL, Raaijmakers A, Korteweg MA, Possanzini C, Boer VO, van de Berg CA, van de Bosch MA, Luijten PR. (31) P MRSI and (1) H MRS at 7 T: initial results in human breast cancer. NMR Biomed. 2011 Dec;24(10):1337-42<br>
3. . Boer VO, Vd Bank BL, van Vliet G, Luijten PR, Klomp DW. Direct B(0) field monitoring and real-time B(0) field updating in the human breast at 7 tesla. Magn Reson Med. 2011 Dec 12. doi: 10.1002/mrm.23272. [Epub ahead of print]<br>
4. van der Kemp WJ, Boer VO, Luijten PR, Wijnen JP, Klomp DW. Increase in SNR for (31) P MR spectroscopy by combining polarization transfer with a direct detection sequence. Magn Reson Med. 2011 Dec 12. doi: 10.1002/mrm.23260. [Epub ahead of print]<br>
5. Wijnen JP, van der Kemp WJ, Luttje MP, Korteweg MA, Luijten PR, Klomp DW. Quantitative (31) P magnetic resonance spectroscopy of the human breast at 7 T. Magn Reson Med. 2011 Dec 28. doi: 10.1002/mrm.23249. [Epub ahead of print]<br>
6. van de Bank BL, Voogt IJ, Italiaander M, Stehouwer BL, Boer VO, Luijten PR, Klomp DW. Ultra high spatial and temporal resolution breast imaging at 7T. NMR Biomed. 2012 Oct 18. doi: 10.1002/nbm.2868. [Epub ahead of print]<br>
7. de Graaf RA, Klomp DW, Luijten PR, Boer VO. Intramolecular zero-quantum-coherence 2D NMR spectroscopy of lipids in the human breast at 7 T. Magn Reson Med. 2013 Mar 6. doi: 10.1002/mrm.24701. [Epub ahead of print]<br>
8. van der Kemp WJ, Boer VO, Luijten PR, Stehouwer BL, Veldhuis WB, Klomp DW. Adiabatic multi-echo 31 P spectroscopic imaging (AMESING) at 7 T for the measurement of transverse relaxation times and regaining of sensitivity in tissues with short T2 * values. NMR Biomed. 2013 Apr 2 doi: 10.1002/nbm.2952. [Epub ahead of print]<br>
9. Klomp DW, Dula AN, Arlinghaus LR, Italiaander M, Dortch RD, Zu Z, Williams JM, Gochberg DF, Luijten PR, Gore JC, Yankeelov TE, Smith SA. Amide proton transfer imaging of the human breast at 7T: development and reproducibility. NMR Biomed. 2013 Apr 4. doi: 10.1002/nbm.2947. [Epub ahead of print]<br>
10.Stehouwer BL, Klomp DW, van den Bosch MA, Korteweg MA, Gilhuijs KG, Witkamp AJ, van Diest PJ, Houwert KA, van der Kemp WJ, Luijten PR, Mali WP, Veldhuis WB. Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla. Eur Radiol. 2013 Nov;23(11):2961-8. doi: 10.1007/s00330-013-2985-9. Epub 2013 Aug 28.<br>
11. de Leeuw H, Stehouwer BL, Bakker CJ, Klomp DW, van Diest PJ, Luijten PR, Seevinck PR, van den Bosch MA, Viergever MA, Veldhuis WB. Detecting breast microcalcifications with high-field MRI. NMR Biomed. 2014 Feb 17. doi: 10.1002/nbm.3089<br>
12. 31P magnetic resonance spectroscopy of the breast and the influence of the menstrual cycle. Stehouwer BL, van der Kemp WJ, Luijten PR, van den Bosch MA, Veldhuis WB, Wijnen JP, Klomp DW.Breast Cancer Res Treat. 2014 Feb 26.<br>
13. Boer VO, Luttje MP, Luijten PR, Klomp DW. Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T. NMR Biomed. 2014 Feb 25. doi: 10.1002/nbm.3096<br>
14. Korteweg MA, Veldhuis WB, Mali WP, Diepstraten SC, Luijten PR, van den Bosch MA, Eijkemans RM, van Diest PJ, Klomp DW. Investigation of lipid composition of dissected sentinel lymph nodes of breast cancer patients by 7T proton MR spectroscopy. J Magn Reson Imaging. 2011 Oct 3. doi: 10.1002/jmri.22820. [Epub ahead of print]<br>
15. Stehouwer BL, Klomp DW, Korteweg MA, Verkooijen HM, Luijten PR, Mali WP, van den Bosch MA, Veldhuis WB. 7T versus 3T contrast-enhanced breast Magnetic Resonance Imaging of invasive ductulolobular carcinoma: First clinical experience. Magn Reson Imaging. 2012 Oct 30. doi:pii: S0730-725X(12)00359-1. 10.1016/j.mri.2012.09.005. [Epub ahead of print]