No registrations found.
ID
Source
Brief title
Health condition
Atrial fibrillation, implantable cardioverter defibrillator, home monitoring, coronary artery disease.
Sponsors and support
Intervention
Outcome measures
Primary outcome
the percentage of patients with AF at 1 or 2 years.
Secondary outcome
1) the time to 10% and 20% of patients with AF.
2) The burden as percentage/day of AF.
3) Occurrence of TIA, stroke or systemic embolism.
4) Cumulative incidence of appropriate and inappropriate ICD therapy.
Background summary
Rationale: Post-myocardial infarction patients with reduced left ventricular ejection fraction (LVEF) are indicated for Implantable Cardioverter-Defibrillator (ICD) therapy as primary prevention for sudden cardiac death (SCD). Timely detection of atrial fibrillation (AF) in ICD patients is clinically important for appropriate treatment for prevention of AF related complications, most importantly stroke, heart failure and inappropriate ICD shocks. Patients with a two- or three chamber ICD and coronary artery disease (CAD) show a higher incidence of AF than age matched controls. If CAD patients with a single chamber ICD carry a similar risk for AF remains unknown. Recently, single chamber ICDs including algorithm based rhythm recorders are developed to investigate the incidence and prevalence of AF.
Objective: To investigate the incidence of new-onset AF in patients with CAD and an impaired LVEF, who will receive a single chamber ICD as primary prevention for SCD.
Study design: This study will be a multicentre observational study. Patients with CAD and
Study population: Patients, with CAD, LVEF <35% and without a history of AF, who are indicated for a single chamber ICD as primary prevention for SCD.
Intervention: Patients will, as per guideline recommendation, receive a single chamber ICD with an algorithm based rhythm recorder.
Main study parameters: Main study parameters are new-onset or silent AF.
The study with regard to a broader research plan: This study will underscore the importance of AF detection in single chamber ICD patients, remote patient monitoring and improvement of patient care. Thereby it may serve as a pilot study for upcoming large international trials on AF detection algorithm in patients with single chamber ICDs.
Study objective
To investigate the incidence of new-onset AF in patients with coronary artery disease and an impaired LVEF, who will receive a single chamber ICD as primary prevention for sudden cardiac death.
Study design
Standard ICD interrogation will take place on a quarterly basis. The occurrence of AF will be monitored via remote monitoring and documented in the eCRF every month, during one year or until we reach an event rate of 10% and 20%.
Intervention
Patients with CAD and
J.R. Groot, de
Meibergdreef 9
Amsterdam 1105 AZ
The Netherlands
020-5669111 (tracer 58921)
j.r.degroot@amc.uva.nl
J.R. Groot, de
Meibergdreef 9
Amsterdam 1105 AZ
The Netherlands
020-5669111 (tracer 58921)
j.r.degroot@amc.uva.nl
Inclusion criteria
• Age between 65 and 80 years
• CAD, evident from a) previous myocardial infarction or b) revascularization through PCI or CABG
• LVEF<35%, quantified on MRI or with nuclear imaging
• Willing and able to sign informed consent and to comply with the protocol and with the follow-up
• Life expectancy > 2 years
Exclusion criteria
• Unwilling or unable to comply with the protocol
• Unwilling to sign informed consent
• Current atrial fibrillation
• A history of atrial fibrillation
• Previous catheter or surgical ablation for atrial fibrillation
• Use of vitamin K antagonist or NOACs
• Use of class 1 or 3 antiarrhythmic drugs for ventricular or supraventricular arrhythmia ` other than AF
• Prosthetic heart valves
• Dilated or hypertrophic cardiomyopathy
• Congenital heart disease for which surgical correction was performed
• Inherited arrhythmia syndrome
• Active malignant disease
• Use of antracyclins in the history
• History of TIA, stroke or systemic embolism
• Being pregnant or of child bearing potential
• Life expectancy<2 years
Design
Recruitment
Followed up by the following (possibly more current) registration
Other (possibly less up-to-date) registrations in this register
No registrations found.
In other registers
Register | ID |
---|---|
NTR-new | NL6732 |
NTR-old | NTR6910 |
CCMO | NL63311.018.17 |
OMON | NL-OMON55649 |