Over recent years, post-processing software has become available that allows co-registration of pre- and post-ablation CECT. This allows three-dimensional quantitative assessment of ablation margins. Such quantification of ablation margin would…
ID
Bron
Verkorte titel
Aandoening
Hepatocellular carcinoma
Ondersteuning
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
Minimal ablation margin that results in a local recurrence rate <10%
Achtergrond van het onderzoek
Problem description
Compared to thermal ablation, the complication rate in surgically treated HCC patients is much higher with an odds ratio of 8.24 (95% CI: 2.12-31.95). Yet, surgical resection yields better results regarding local recurrence (HR 0.38 (95% CI: 0.17-0.84)). Therefore, surgical resection remains the treatment of choice for most patients with BCLC 0/A HCC, despite higher morbidity and mortality rates. For thermal ablation to become truly competitive with surgical resection, the issue of local recurrence needs to be addressed.
Ablation systems have predefined algorithms, based on in vitro experiments, to predict size and shape of the ablation. In general, ablations setting are chosen that would result in complete tumor ablation with a safety margin of >5mm, but the actual ablation zone may be smaller than expected and deformed as a result of factors such as inhomogeneous tissue density, liver cirrhosis and heat-sink.
After surgical resection, a pathologist examines the resected specimen to confirm complete resection. After ablation, confirmation of successful ablation can only be obtained using imaging modalities. Currently there is no validated, standardized method to accurately determine safety margins. Most commonly, the interventional radiologist performing the procedure estimates the safety margins by visual qualitative assessment of pre- and post-ablation contrast-enhanced CT (CECT). This method is associated with high interobserver variability and lacks accuracy. There is a need for a method that allows more accurate assessment of safety margins after ablation.
Solution
Over recent years, post-processing software has become available that allows co-registration of pre- and post-ablation CECT. This allows three-dimensional quantitative assessment of ablation margins. Such quantification of ablation margin would allow immediate evaluation of ablation margins and reablation during the same treatment session if margins are deemed to be insufficient. It would potentially be the equivalent of the frozen section that is used for real-time margin control during surgery.
Retrospective studies have demonstrated the potential value of quantitative assessment of ablation margins after thermal ablation, but this has neither been validated in prospective studies nor in larger patient groups. In a prospective, multi-center, non-experimental study in patients undergoing ablation for BCLC 0/A/B HCC, safety margins will be quantitatively assessed using dedicated co-registration software.
The aim of this project is to correlate ablation margins with outcome to determine the relationship between ablation margins and local recurrence and set the optimal threshold for minimal ablation margin.
Doel van het onderzoek
Over recent years, post-processing software has become available that allows co-registration of pre- and post-ablation CECT. This allows three-dimensional quantitative assessment of ablation margins. Such quantification of ablation margin would allow immediate evaluation of ablation margins and reablation during the same treatment session if margins are deemed to be insufficient. It would potentially be the equivalent of the frozen section that is used for real-time margin control during surgery.
Onderzoeksopzet
- Registration
- Ablation
- Follow-up every 3-4 months until 3 years
Algemeen / deelnemers
Wetenschappers
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
· Age 18 years or above
· HCC very early (0) or early stage (A) according to the BCLC staging system OR HCC intermediate stage (B) with a maximum of two lesions of ≤5cm each
· Either de novo or recurrent HCC (prior locoregional therapy is allowed in the study)
· Candidate for percutaneous thermal ablation as discussed in a multidisciplinary tumor board
· Absence of any psychological, familial, sociological or geographical condition potentially hampering compliance with the study protocol and follow-up schedule
· Written informed consent
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
· Estimated GFR <30 ml/min
· Known severe allergy to contrast medium
· ASA classification higher than 3
· Child Pugh C
· ECOG ≥1 (tumor-related)
· Portal vein tumor invasion
· Extrahepatic metastasis
· Neoadjuvant transarterial therapy (TACE, TAE or TARE), i.e. combination therapy of transarterial therapy with ablation
· Uncorrectable coagulopathy
Opzet
Deelname
Voornemen beschikbaar stellen Individuele Patiënten Data (IPD)
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL9713 |
CCMO | NL75744.058.21 |
OMON | NL-OMON55994 |