Are hemodynamic values obtained by the non invasive hemodynamic measuring device TL-400 comparable with the values obtained by the standard invasive hemodynamic measuring devices (transpulmonary thermodilution (TPTD) (PiCCO system; Pulsion Medical…
ID
Bron
Aandoening
hemodynamic changes, low blood pressure, fluid challenge, vasopressant/inotropic agent administration, measurement cardiac output, measurement blood pressure, non invasive cardiac output measurement. hemodynamische veranderingen , vocht bolus, cardiac output meting, bloeddruk meting, non invasieve cardiac output meting
Ondersteuning
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
Cardiac output, systolic blood pressure, diastolic blood pressure, mean blood pressure, stroke volume
Achtergrond van het onderzoek
Perioperative validation study to compare TL-400 hemodynamic device with the standard PiCCO measuring device by comparing simultaneous CO and BP measurements at predetermined time points
Doel van het onderzoek
Are hemodynamic values obtained by the non invasive hemodynamic measuring device TL-400 comparable with the values obtained by the standard invasive hemodynamic measuring devices (transpulmonary thermodilution (TPTD) (PiCCO system; Pulsion Medical Systems) or pulmonary artery catheter (PAC)
Onderzoeksopzet
Simultaneous CO and BP measurements were performed at seven predetermined time points (T1-T7): after induction of general anaesthesia but before surgical incision (T1), 30 minutes after start CRS (T2), 30 minutes before end of CRS or halfway iv chemotherapy (T3), after CRS and before the start HIPEC procedure (T4), halfway through HIPEC (T5), after the end of chemotherapy perfusion (T6), end of surgery (T7)
Onderzoeksproduct en/of interventie
After insertion of the standard invasive measuring device, the TL 400 sensor is placed around the wrist at the point where the radial artery is palpable over the head of the os radius.
Algemeen / deelnemers
L. Baggen
Geert-Grooteplein-zuid 10 (route 715), Postbus 9101
Nijmegen 6500 HB
The Netherlands
+31(0)243614406
Lonneke.Baggen@radboudumc.nl
Wetenschappers
L. Baggen
Geert-Grooteplein-zuid 10 (route 715), Postbus 9101
Nijmegen 6500 HB
The Netherlands
+31(0)243614406
Lonneke.Baggen@radboudumc.nl
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
All patients receiving invasive hemodynamic monitoring as standard perioperative monitoring are eligible for inclusion.
Age > 18 years
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
Severe peripheral vascular disease
Severe tricuspid or aortic valve regurgitation
Anatomical abnormalities at the wrist so the TL-400 brace cannot be applied.
Refusal of the patient
Opzet
Deelname
Voornemen beschikbaar stellen Individuele Patiënten Data (IPD)
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Geen registraties gevonden.
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL6812 |
NTR-old | NTR6998 |
Ander register | METC RadboudUMC : 2017-3203 |