Awake craniotomy improves safety and efficacy during surgery for glioblastoma in eloquent areas
ID
Bron
Verkorte titel
Aandoening
Glioblastoma
Ondersteuning
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
1. Proportion of patients with NIHSS (National Institute of Health Stroke Scale) deterioration at 6 weeks post-surgery, where deterioration is defined as at least one point increase in total NIHSS score compared to baseline
2. Proportion of patients without residual contrast-enhancing tumour on postoperative MRI, where residual tumour is defined as contrast-enhancement with a volume more than 0.175 cm3.
Achtergrond van het onderzoek
The trial is designed as a multicenter randomized controlled study. 246 patients with presumed Glioblastoma Multiforme in eloquent areas on diagnostic MRI will be selected by the neurosurgeons according the eligibility criteria (see under). After written informed consent is obtained, the patient will be randomized for an awake craniotomy (AC) (+/-123 patients) or craniotomy under general anesthesia (GA) (+/-123 patients), with 1:1 allocation ratio. Under GA the amount of resection of the tumour has to be performed within safe margins as judged by the surgeon during surgery. The second group will be operated with an awake craniotomy procedure where the resection boundaries for motor or language functions will be identified by direct cortical and subcortical stimulation. After surgery, the diagnosis of GBM will have to be histologically confirmed. If GBM is not histologically confirmed, patients will be considered off-study and withdrawn from the study. These patients will be followed-up according to standard practice. Thereafter, patients will receive the standard treatment with concomitant Temozolamide and radiation therapy and standard follow up. Total duration of the study is 5 years. Patient inclusion is expected to take 4 years. Follow-up is 1 year after surgery. Statistical analysis, cost benefit analysis and article writing will take 3 months.
Doel van het onderzoek
Awake craniotomy improves safety and efficacy during surgery for glioblastoma in eloquent areas
Onderzoeksopzet
Baseline - 48 hours postoperatively - 6 weeks postoperatively - 3 months postoperatively - 6 months postoperatively
Onderzoeksproduct en/of interventie
Awake craniotomy; craniotomy under general anesthesia; NIHSS; EQ-5D; EORTC QLQ-C30; EORTC QLQ-BN20
Publiek
Wetenschappelijk
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
1. Age ≥18 years and ≤ 90 years
2. Tumor diagnosed as Glioblastoma Multiforme on MRI with distinct ring-like pattern of
contrast enhancement with thick irregular walls and a core area reduced signal
suggestive of tumour necrosis as assessed by the surgeon
3. Tumors situated in or near eloquent areas; motor cortex, sensory cortex, subcortical
pyramidal tract or speech areas as indicated on MRI (Sawaya Grading II and II) [47]
4. The tumor is suitable for resection (according to neurosurgeon)
5. Karnofsky performance scale 80 or more
6. No severe aphasia or dysphasia; able to communicate during an awake procedure
7. Written Informed consent
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
1. Tumors of the cerebellum, brain stem or midline
2. Multifocal contrast enhancing lesions
3. Substantial non-contrast enhancing tumor areas suggesting low grade gliomas with malignant transformation
4. Medical reasons precluding MRI (eg, pacemaker)
5. Inability to give consent because of or language barrier
6. Psychiatric history
7. Previous brain tumour surgery
8. Previous low-grade glioma.
9. Second primary malignancy within the past 5 years with the exception of adequately treated in situ carcinoma of any organ or basal cell carcinoma of the skin.
10. Severe aphasia or dysphasia
Opzet
Deelname
Voornemen beschikbaar stellen Individuele Patiënten Data (IPD)
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Geen registraties gevonden.
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL7589 |
Ander register | METC EMC : MEC-2018-1564 |