We postulate that exhaled breath sampling by an electronic nose can distinguish and adequately identify smell-prints from: 1. Atopic patients without airway obstruction 2. Non-atopic patients without airway obstruction 3. Atopic patients with…
ID
Bron
Verkorte titel
Aandoening
English: Asthma. Atopy. Wheezing. exhaled breath analysis.
Dutch: Astma. Atopie. Piepende ademhaling. Uitademingslucht analyse.
Ondersteuning
Central Military Hospital, Ministery of Defence, Utrecht, The Netherlands.
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
Electronic nose smellprint of a vital capacity volume breath sample.
Achtergrond van het onderzoek
Background and rationale:
Diagnosing and monitoring of asthma is based on its clinical presentation and repeated measurement of lung function. However, these tests are time-consuming and not widely applicable. Furthermore, differential diagnosis, (sub)phenotyping and monitoring of asthma remain difficult, which hinders clinical management, especially in primary care.
Simple and fast diagnostic methods in asthma are therefore needed, and improving accuracy and cost-effectiveness of diagnosing and monitoring asthma can contribute to improved management of the disease.
Using exhaled air as the source for measuring biomarkers is attractive because it is noninvasive and allows repeated sampling. Heterogeneity in asthma is also likely to be reflected in the composition of the exhaled air, which is known to contain thousands of volatile organic compounds (VOCs) that are derived from various metabolic pathways taking place in the lung and elsewhere in the body. These VOCs, alone or in combination, can potentially be used as biomarkers for the disease in general and more specifically, for its several subclasses.
Electronic nose (eNose) technology is based on an array of sensors reacting to the many volatile organic compounds (VOC's) in breath, combined with pattern recognition algorithms. Recently, Dragonieri et al demonstrated that an electronic nose was able to distinguish the smell-prints of exhaled breath from patients with asthma and healthy controls (JACI 2008).
The current study aims to estimate the diagnostic accuracy of exhaled breath measurement using the electronic nose in asthma and atopy, following the STARD criteria.
Hypothesis:
We postulate that exhaled breath sampling by an electronic nose can distinguish and adequately identify smell-prints from:
1. Atopic patients without airway obstruction
2. Non-atopic patients without airway obstruction
3. Atopic patients with airway obstruction
4. Non-atopic patients with airway obstruction
Aim of the study:
To estimate the diagnostic accuracy of exhaled breath measurement using the electronic nose in asthma and atopy.
Outcome parameters:
The primary outcome parameter is the smell-print provided by the electronic nose.
Subjects:
Patients (>16 years old) referred to the department of Pulmonology of the Central Military Hospital (CMH), Utrecht for evaluation of asthma and/or atopy will be included.
Design:
The study comprises prospective enrollment of possible new patients from a population suspect for asthma and of healthy controls.
In this validation phase of the study, the diagnostic accuracy of the electronic nose is determined in a screening setting for asthma in population with an intention to diagnoses. Subsequently, the specificity and negative predictive value and the sensitivity and positive predictive value will be calculated in relation to the gold standard phenotypes.
Methods of measurement:
Electronic nose: the Cyranose 320 (Smith Detections, Pasadena, Ca, USA), a handheld portable chemical vapor analyzer, containing a nanocomposite sensor array with 32 polymer sensors and The DiagNose (C-it, Zutphen, Nederland), a handheld portable chemical vapor analyzer, containing an array of three microhotplate type metaloxide sensors in conjunction with factory calibrated temperature and relative humidity sensors. Patients will breathe normally through a mouthpiece, connected to a three-way non-re-breathing valve and an inspiratory VOC-filter (A2, North Safety, NL) for 5 minutes. After a single deep inspiration the patient exhales a vital capacity volume into a Tedlar bag connected to the expiratory port. Within 30 minutes the electronic nose will be connected to the Tedlar bag, followed by 1 minute sampling of the exhaled air.
Skin prick test/RAST: allergy testing.
Spirometry: prebronchodilator spirometry according to ERS/ATS recommendations.
Exhaled NO: using the Niox Aerocrine according to the ATS recommendations (ATS NO).
Exhaled CO: using a Bedfont Micro Smokerlyzer (Bedfont Scientific LTD, Rochester, England) (Middleton, Morice).
Bronchial responsiveness by histamine challenge according to ERS/ATS recommendations.
Symptoms:
Questionnaires for assessing symptoms of asthma and for co-morbidity will be used.
Analysis:
The smell prints will be analysed by off-line learning software (Dept. Medical Statistics, AMC, LUMC). Double cross-validatory implementation of linear discriminant analysis on principal component reduction will be performed using SPSS software.
Study management:
Primary investigator: Niki Fens, MD, Prof. Peter J Sterk, MD, PhD, Noël Schlösser, MD.
Ethics: The LUMC and AMC Medical Ethics Committees have approved the protocol entitled: 'The electronic nose in the diagnostic assessment of airway disease' (05/119 LUMC, 07/153 AMC).
The Medical Ethics Committee of the Ministry of Defence (Central Military Hospital) has approved the protocol.
Doel van het onderzoek
We postulate that exhaled breath sampling by an electronic nose can distinguish and adequately identify smell-prints from:
1. Atopic patients without airway obstruction
2. Non-atopic patients without airway obstruction
3. Atopic patients with airway obstruction
4. Non-atopic patients with airway obstruction
Onderzoeksopzet
All measurements will take place in a single visit of approx. 1 1/2 hour.
Onderzoeksproduct en/of interventie
None: diagnostic study.
Publiek
Academic Medical Center (AMC) <br>
University of Amsterdam<br>
Department of Pulmonology <br> F5-260 <br>
P.O.Box 22660
Niki Fens
Meibergdreef 9
1100 DD
Amsterdam 1105 AZ
The Netherlands
+31 (0)20 5664359
N.Fens@amc.nl
Wetenschappelijk
Academic Medical Center (AMC) <br>
University of Amsterdam<br>
Department of Pulmonology <br> F5-260 <br>
P.O.Box 22660
Niki Fens
Meibergdreef 9
1100 DD
Amsterdam 1105 AZ
The Netherlands
+31 (0)20 5664359
N.Fens@amc.nl
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
1. ≥ 17 years
2. Referred to the Central Military Hospital, dept. of Pulmonology for evaluation of asthma and/or atopy.
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
1. < 17 years
2. Present upper respiratory infection or common cold, or in the past 2 weeks
3. Asthma exacerbation < 4 weeks
4. Present dental problems:
paradontitis, recent extraction of tooth (< 2 weeks)
5. Chronic tonsillitis or sinusitis
6. Eating/drinking/smoking/brushing teeth/chewing gum/mint < 3 hours before eNose measurement
7. Use of long-acting inhaled ¦Â-agonists < 24 hours and/or use of short-acting ¦Â-agonists < 12 hours and/or use of inhaled corticosteroids < 24 hours
8. Known thyroid dysfunction and/or use of Levothyroxine
9. Known diagnosis of diabetes mellitus
10. Failure to complete eNose measurement
11. Not willing to participate in the study or lack of understanding
Opzet
Deelname
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Geen registraties gevonden.
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL1339 |
NTR-old | NTR1398 |
Ander register | : CMH2008000627-037 |
ISRCTN | ISRCTN wordt niet meer aangevraagd |