(1) Time until documented recurrence of AF or SVT will be shorter in the study population compared to the standard of care.
ID
Bron
Verkorte titel
Aandoening
Atrial Fibrillation (AF)
eHealth
Ambulant monitoring
Monitoring
Catheter ablation
Pulmonary vein isolation (PVI)
diagnostic accuracy study
Ondersteuning
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
(1) Detection and time till detection of recurrence of AF<br>
(2) Use of medication post PVI<br>
(3) Time until AAD are ceased<br>
(4) Quality of Life (AFEQT-questionnaire)<br>
(5) Healthcare visits (cardio-vascular related)<br>
(6) additional diagnostic testing
Achtergrond van het onderzoek
Atrial fibrillation is a major public health problem and is the most common cardiac arrhythmia, affecting an estimated 4.5 million people in Europe. The true prevalence of atrial fibrillation is likely underestimated because episodes are often sporadic; therefore, it is challenging to detect and record an occurrence in a “real world” setting. Catheter ablation, pulmonary vein isolation (PVI), has shown to be a safe and effective treatment strategy for AF and therefore it has become an established invasive strategy for drug refractory AF. After PVI, 30-60% of patients show recurrent episodes of AF. Previous studies have demonstrated that the overall prevalence of undiagnosed AF is underestimated, and active screening and monitoring should be pursued. Prompt recording of a 12-lead ECG is an effective and cost-effective method to document chronic forms of AF, but paroxysmal AF is more often missed. The technology to detect paroxysmal, self-terminating AF episodes is rapidly evolving. Evidence shows that prolonged ECG monitoring enhances the detection of undiagnosed AF. The detection of asymptomatic and paroxysmal AF by new technologies, such as smartphone cases with ECG electrodes, smart watches, and blood pressure machines with AF detection algorithms, has not yet been formally evaluated against an established arrhythmia detection method, but looks promising. The use and implementation of electronic-health (eHealth) is being encouraged by the Hearth Rhythm Society(HRS) and European Hearth Rhythm Association (EHRA), as stated in their position statements of 2012 and 2015. This study will evaluate a mobile eHealth device (Kardia) to detect recurrent atrial arrhythmias after PVI and to evaluate the impact on patient outcomes and quality of life.
Objective of the study:
Optimise post PVI management using ambulant continuous patient-driven eHealth monitoring after catheter ablation in the treatment of atrial fibrillation.
Primary Objective:
1) Determine the effect of eHealth on clinical management, outcomes and quality of life compared to standard of care follow up after pulmonairy vein isolation in the treatment of AF.
Secondary Objectives:
1) Determine the diagnostic performance/accuracy and reliability
2) Determine the usability and applicability in daily practice.
Study design: Longitudinal cohort study
Study population: 100 patients who undergo catheterablation for AF
Primary study parameters/outcome of the study:
Effect on post-PVI management:
1) Arrhythmia detection (AF, Aflut, AT, SVT)
2) Time until arrhythmia detection
3) Medication management (AAD, OAC)
4) Time until discontinuation AAD and/or OAC
5) AF-related healthcare visits
Secundary study parameters/outcome of the study (if applicable):
Diagnostic accuracy study
1) Sensitivity
2) Specificity
3) positive and negative predicting values
4) Cohens kappa Kardia (holter – kardia and kardia – cardiologist)
Usefulness and applicability eHealth
1) Ease of use
2) Availability when demanded
3) Technical quality
4) Compliance
5) User satisfaction (patient and physician)
6) Quality of Life
Nature and extent of the burden and risks associated with participation, benefit and group relatedness (if applicable):
Patients receive additional means for cardiac rhythm monitoring to encourage self-management and early detection. Thereby, recurrent cardiac arrhythmias might be recognised earlier and improved quality of life might be achieved earlier. Standard of care will not be restricted unless the treating cardiologist deems it appropriate.
Doel van het onderzoek
(1) Time until documented recurrence of AF or SVT will be shorter in the study population compared to the standard of care.
Onderzoeksopzet
- informed consent
- prior to ablation concomitant 7-day holter and use of eHealth (diagnostic accuracy study)
- post ablation continuous eHealth use in addition to regular care
- study contact/visits 4, 8 and 12 months
*(1) symptoms, medication and health care visits
*(2) AFEQT (quality of life - atrial fibrillation)
*(3) eHealth questionnaire about applicability and usability
Holter after 12 months
Onderzoeksproduct en/of interventie
patients recieve an eHealth mobile device to monitor for recurrence of AF or other SVT during the first year after ablation
Publiek
M.N. Klaver
Koekoekslaan 1
Nieuwegein 3435 CM
The Netherlands
088-320-0900
m.klaver@antoniusziekenhuis.nl
Wetenschappelijk
M.N. Klaver
Koekoekslaan 1
Nieuwegein 3435 CM
The Netherlands
088-320-0900
m.klaver@antoniusziekenhuis.nl
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
(1) Patients 18 years and over
(2) Documented palpitation driven paroxysmal atrial fibrillation or symptomatic (long-standing) persistent atrial fibrillation
(3) Scheduled for index PVI procedure
(4) Succesfully utilises a smartphone or tablet, compatible with the required software prior to enrolment
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
(1) Patients monitored with continuous heart rhythm monitor (e.g. pacemaker, ICD, ILR)
(2) Participation in a conflicting study
(3) Inability or unwillingness to complete the full study protocol
Opzet
Deelname
Voornemen beschikbaar stellen Individuele Patiënten Data (IPD)
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL6956 |
NTR-old | NTR7144 |
CCMO | NL62457.100.17 |
OMON | NL-OMON44247 |