Test weighing using a double-check weighing method is precise in determining infant intake: in more than 90% of weighings test weighing will be within 5ml of the actual amount drunk
ID
Bron
Aandoening
breast feeding
Keywords:
English
-Test weighing
-breastfeeding
-Milk intake
-Precision
NL:
-Test wegen
-Borstvoeding
-Intake
-Precisie
Ondersteuning
Tegelseweg 210
5915 BL Venlo
Tegelseweg 210
5915 BL Venlo
Onderzoeksproduct en/of interventie
Uitkomstmaten
Primaire uitkomstmaten
precision of test weighing, using a double-check weighing method for 2 scales in 2 groups: intake up to 20cc and 20cc and more
Achtergrond van het onderzoek
Rationale: test weighing is used extensively to assess intake in breastfed infants. Data regarding its precision however differ and are contradictory. There is discussion about the technique and scales used. Our goal is to use a double check weighing procedure on 2 different scales and determine precision in a large group of newborn infants.
Objective: to determine the precision of test weighing on 2 different scales in 2 different intake groups: feeds up to 20 cc and feeds of 20cc and more.
Study design: diagnostic accuracy study in a cohort of newborn infants.
Study population: All exclusively bottle or nasogastric fed infants in the neonatal ward are deemed eligible.
Intervention: infants are weighed twice before and twice after a feed in a standardized way by an independent investigator, unaware of the amount drunk. The weights before, as well as the weights after feeding, have to be within 5 grams. Otherwise a third weight has to be obtained. The difference between the averaged weights before and the averaged weights after feeding is taken to reflect intake in cc. The actual amount drunk will be determined by weighing the bottles before and after feeding.
Main study parameters/endpoints: precision will be calculated by determining the standard deviation of the mean of the difference between the test weighing amount and actual amount drunk.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness: Risks are negligible. Weighing is a routine procedure done in all neonatal wards. Weighing will be done in infants who are about to be fed, so it will not interfere with sleep or resting.
Doel van het onderzoek
Test weighing using a double-check weighing method is precise in determining infant intake: in more than 90% of weighings test weighing will be within 5ml of the actual amount drunk
Onderzoeksopzet
not applicable.
Onderzoeksproduct en/of interventie
none
Publiek
VieCuri Medical Center
Tegelseweg 210
5915 EA Venlo
Venlo
The Netherlands
0773205730
geraldjaspers@hotmail.com
Wetenschappelijk
VieCuri Medical Center
Tegelseweg 210
5915 EA Venlo
Venlo
The Netherlands
0773205730
geraldjaspers@hotmail.com
Belangrijkste voorwaarden om deel te mogen nemen (Inclusiecriteria)
-Admission in the neonatal ward.
-Bottle or fully nasogastric fed infants
Belangrijkste redenen om niet deel te kunnen nemen (Exclusiecriteria)
-If the treating pediatrician finds the infant to be too unstable for the extra weighing.
-If, according tot the treating pediatrician, the infant requires minimal handling.
-If the parents of caregivers speak insufficient Dutch to be able to give informed consent
Opzet
Deelname
Opgevolgd door onderstaande (mogelijk meer actuele) registratie
Geen registraties gevonden.
Andere (mogelijk minder actuele) registraties in dit register
Geen registraties gevonden.
In overige registers
Register | ID |
---|---|
NTR-new | NL4542 |
NTR-old | NTR4685 |
Ander register | : ABR48368 |
Samenvatting resultaten
Savenije, O.E. and P.L. Brand, Accuracy and precision of test weighing to assess milk intake in newborn infants. Archives of disease in childhood. Fetal and neonatal edition, 2006. 91(5): p. F330-2